ESS
⚡ The ESS 350 × 250 × 120 mm metal distribution enclosure is designed for wall-mounted installation of electrical components, terminal blocks, control equipment and cable connections. Its 0.5 mm steel enclosure includes a mounting panel and a key-lockable door and provides IP31 protection.
⚡ The ESS 350 × 250 × 120 mm metal distribution enclosure is designed for wall-mounted installation of electrical components, terminal blocks, control equipment and cable connections. Its 0.5 mm steel enclosure includes a mounting panel and a key-lockable door and provides IP31 protection.
⚡ The ESS 350 × 250 × 150 mm metal distribution enclosure is designed for wall-mounted installation of electrical protection devices, terminals, relays, controllers and cable connections. Its 0.5 mm steel body includes a removable mounting panel and a 150 mm depth suitable for larger components.
⚡ The ESS 350 × 250 × 150 mm metal distribution enclosure is designed for wall-mounted installation of electrical protection devices, terminals, relays, controllers and cable connections. Its 0.5 mm steel body includes a removable mounting panel and a 150 mm depth suitable for larger components.
⚡ The ESS MSQ-30 150/5 A current transformer is designed to connect electricity meters and measuring instruments to power circuits carrying up to 150 A. It converts a 150 A primary current into a standard 5 A secondary current, enabling safe and accurate measurement without passing the full load current through the meter.
⚡ The ESS MSQ-30 150/5 A current transformer is designed to connect electricity meters and measuring instruments to power circuits carrying up to 150 A. It converts a 150 A primary current into a standard 5 A secondary current, enabling safe and accurate measurement without passing the full load current through the meter.
⚡ The ESS 200/5 A current transformer converts primary current up to 200 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its 40:1 transformation ratio enables safe and accurate energy measurement at facilities with high electrical loads.
⚡ The ESS 200/5 A current transformer converts primary current up to 200 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its 40:1 transformation ratio enables safe and accurate energy measurement at facilities with high electrical loads.
⚡ The ESS TTN-40 400/5 A current transformer converts primary current up to 400 A into a standard 5 A measuring current for electricity meters, ammeters and AMR systems. Its class 0.5 accuracy, 5 VA burden and through-type construction suit commercial and technical metering in switchboards.
⚡ The ESS TTN-40 400/5 A current transformer converts primary current up to 400 A into a standard 5 A measuring current for electricity meters, ammeters and AMR systems. Its class 0.5 accuracy, 5 VA burden and through-type construction suit commercial and technical metering in switchboards.
⚡ The ESS 50/5 A current transformer converts primary current up to 50 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its 10:1 transformation ratio makes it suitable for technical and commercial electricity metering.
⚡ The ESS 50/5 A current transformer converts primary current up to 50 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its 10:1 transformation ratio makes it suitable for technical and commercial electricity metering.
⚡ The ESS TTN-30 100/5 A current transformer converts primary current up to 100 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its accuracy class 0.5 and 5 VA rated burden make it suitable for commercial and technical energy metering in electrical panels and distribution equipment.
⚡ The ESS TTN-30 100/5 A current transformer converts primary current up to 100 A into a standard 5 A measuring current for electricity meters, ammeters and monitoring systems. Its accuracy class 0.5 and 5 VA rated burden make it suitable for commercial and technical energy metering in electrical panels and distribution equipment.
⚡ The ESS TSD-15 kVA wall-mounted servo voltage stabilizer is designed to protect single-phase electrical equipment against low and high mains voltage. It operates across a 100–250 V input range, automatically regulates the voltage and suits homes, offices, shops and other facilities with a total load of up to 15 kVA.
⚡ The ESS TSD-15 kVA wall-mounted servo voltage stabilizer is designed to protect single-phase electrical equipment against low and high mains voltage. It operates across a 100–250 V input range, automatically regulates the voltage and suits homes, offices, shops and other facilities with a total load of up to 15 kVA.
⚡ The ESS TSD-20 kVA wall-mounted servo voltage stabilizer is designed to protect single-phase electrical equipment against low, high and unstable mains voltage. It operates across a wide 100–250 V input range, provides smooth regulation with a stated accuracy of 2% and suits homes, offices, shops, workshops and other high-load facilities.
⚡ The ESS TSD-20 kVA wall-mounted servo voltage stabilizer is designed to protect single-phase electrical equipment against low, high and unstable mains voltage. It operates across a wide 100–250 V input range, provides smooth regulation with a stated accuracy of 2% and suits homes, offices, shops, workshops and other high-load facilities.
⚡ The ESS M1-250 3P 250A circuit breaker is designed to protect three-phase electrical networks and equipment against overloads and short circuits. Its three-pole design disconnects all three phases simultaneously, with a rated current of 250 A and a breaking capacity of 35 kA.