Вы получите уведомление при снижении стоимости товара на указанные Вами контакты
This item sale 3 countsESS-63 MSL8 50A circuit breaker
⚡ The ESS-63 MSL8 50A is used for switching and protecting electrical circuits. The model has a rated current of 50 A and, according to the Schetchik.uz product listing, is intended for a 380 V three-phase network.
During normal operation, the breaker supplies current to connected equipment. If the load remains above the permissible level or a short circuit occurs, the breaker automatically disconnects the line. This helps protect the cable against overheating, insulation damage and fire risk.
🛡️ Main functions
- Overload protection — disconnection when current remains above the permitted level;
- short-circuit protection — rapid disconnection during a sharp fault-current increase;
- manual switching — allows the circuit to be isolated for servicing;
- fault isolation — helps limit the consequences of an electrical fault.
🔌 Confirmed specifications
- Brand: ESS;
- series: ESS-63 / MSL8;
- rated current: 50 A;
- series current range: 1–63 A;
- supply voltage: 380 V;
- network type: three-phase;
- series versions: 1P, 2P and 3P;
- warranty: 36 months;
- condition: new.
✅ Key advantages
- 50 A rated current for correctly designed circuits;
- automatic protection against dangerous overcurrent;
- short-circuit protection;
- manual line isolation;
- suitable for installation in a distribution board;
- applicable to residential and commercial facilities;
- 36-month warranty;
- mounting parts included.
🏠 Applications
- incoming and branch circuits in private houses;
- shops, offices and administrative premises;
- workshops and light industrial facilities;
- electrical distribution boards;
- lighting and socket circuits where the calculated load is suitable;
- pumps, ventilation and other equipment following an electrical calculation.
⚠️ What to verify before purchase
The series designation includes 1P, 2P and 3P versions. Since the specific product page identifies this item as three-phase, the exact number of poles should be verified from the marking on the breaker body.
Also verify:
- the tripping characteristic, such as B, C or D;
- breaking capacity in kA;
- exact number of poles;
- permitted conductor cross-section;
- manufacturing standard;
- wiring diagram.
💡 Important: a 50 A circuit breaker must be selected according to the permissible current of the cable, not only the total power of connected equipment. Installation and terminal tightening must be performed by a qualified electrician.