Ташкент
Ваш город Ташкент?
">Address: 34, Ashrafi str., Tashkent | Landmark: Samarkand cafe, Yashnabad RES.Opening hours: Mo-Fr, 9:00-18:00 | Sa-Su, 9:00-16:00Log in / Sign up
+998 71 200 18 00Order call
Ташкент
Ваш город Ташкент?
Catalog

3-phase Electricity meter | Energomera CE-308 S31 533 | 380V 5A

(0) Leave a review
SKU: 20009676
In stock: There are 1 pieces left
2,990,000 sum
Notify me of a price reduction
Notify me of a price reduction
Ваша просьба принята!

Вы получите уведомление при снижении стоимости товара на указанные Вами контакты
Your E-mail
Your telephone number
- Fields must be filled in
Checking...
Total views of this page: 1687
This item sale 9 counts
Delivery information to
Courier
Self-delivery
in Tashkent - 100% prepayment
Рассчитываем стоимость доставки...
in the Republic - 100% prepayment
Рассчитываем стоимость доставки...
Self-delivery
Рассчитываем стоимость доставки...

Description

Multifunctional three-phase electricity meter of the energy meter CE 308 S31 543 OAA SYUVJLFZ SPDS of direct and transformer switching. Fully complies with the requirements of electricity metering. The meter is maximally protected from theft of electricity and is used as part of the ASKUE to transmit the measured parameters to the control room for monitoring, accounting and distribution of electric energy.

FEATURES:
Support for the exchange protocol IEC 61107 – 2011, IEC 62056 SPODES /DLMS, IEC 60870-5-104
Versions with communication modules PLC G3, RS485, RS485+RS485, RS485+GSM/GPRS, GSM/GPRS.
Measurement of electricity quality indicators according to class "S":
positive and negative voltage deviation;
network frequency deviation;
duration and depth of voltage failure;
duration and maximum overvoltage value;
power supply interruptions.
Measurement of network parameters:
voltage frequencies;
phase currents;
phase voltages;
angles between current and voltage in phases;
phase-to-phase (linear) voltages;
power factor by phases and in total;
angles between current and voltage in phases;
active power by phases and in total;
reactive power by phases and in total;
full power in phases and in total.
Information protection.
Protection against unauthorized opening (electronic seals).
Magnetic field sensor.
Event logs.
Maintaining 60 types of events in two logs, taking into account the time of violations:
Counter Event Log;
Log of settings changes.
Maintaining a retrospective of accounting:
Recording of accounting data (in total and according to tariffs) for active and reactive energy when the day changes.
Recording of accounting data (in total and according to tariffs) for active and reactive energy during the change of months (with a programmable end date of the billing period).
Recording of accounting data (in total and according to tariffs) for active and reactive energy during the change of years.
Recording of accounting data (in total and according to tariffs) for active and reactive energy by events or command.
Maintaining a load profile, with the ability to configure the type of stored parameters and averaging time.
Analysis of the quality of electricity.
Monitoring of the consumed active power.
Control of the consumed "instantaneous power".
Monitoring of active energy consumption.
Monitoring of the supply network voltage.
Current monitoring.
Network frequency control.
Control of the sequence of alternating phases.
Phase break control.
Control of the oncoming power flow.
Alarm relay.
Telemetry outputs with the possibility of using them as a "relay".
Beep.
Signaling via the interface.
Self-diagnosis.
A mechanism for flexibly adjusting the response to events that occur in the counter.
Displaying information on the LCD accompanied by OBIS codes.
Managing the load of the consumer according to a given schedule.

specifications:
The average time to failure is 220000 hours.
The verification interval is 16 years.
The average service life is 30 years.
The warranty period is 7 years.

IN THE PACKAGE:
Counter;
Passport;
Warranty card;
User Manual;
Box.

Characteristics

Phase3-phase
Amperage5 A
Installation objectProduction, Solar panel, Company
Connecting ASKUGYes
Certificate (years):4 - company, 8 - individual
BrandEnergomera
Data transferGPRS/GSM 900/1800, RS-485, Optoport
Number of tariffs8
Direction of accountingActive, Reactive
Accurasy (active) %0.2
Accurasy (reactive) %0.5
Sensitivity threshold m3/h0.02
Rated frequency50 Hz
GroundingYes
Number of ports10
Maximum cross-section of the connected wire (mm)5
EquipmentDevice, Box, Passport, Certificate, Manual
Size (length-width-height)215 × 175 × 72 mm
Package size (length-width-height)250 × 180 × 80 mm
Weight (net)965 g
ColorBeige
Archive storage period10 years
Guarantee36 mo.
Life time30 years
Working temperature-40 — 70 °C
ConditionNew
CountryRussia
IKPU09028001005000016

3-phase Electricity meter | Energomera CE-308 S31 533 | 380V 5A reviews

About this product reviews yet. Be the first!
×
Contacts
Our address:
Address: 34, Ashrafi str., Tashkent | Landmark: Samarkand cafe, Yashnabad RES.
Opening hours: Mo-Fr, 9:00-18:00 | Sa-Su, 9:00-16:00
×
Заказать обратный звонок
Номер телефона*
Email
Ваше имя*
Комментарий*
  
×