GSM-GPRS modem Bitcord RS 485-232 for GSM/GPRS data transmission, RS-485 and RS-232 interfaces
BitCord RS-485/RS-232 GSM/GPRS data-transmission modem
📡 The BitCord RS-485/RS-232 is an industrial modem designed to transmit data remotely from meters, controllers, flow computers and other equipment through a GSM/GPRS mobile network.
It supports 2G communication in the GSM 900/1800 bands and provides two industrial serial interfaces: RS-485 and RS-232.
🔄 Operating principle
A connected meter or controller generates consumption and equipment-status data. The modem reads this information through RS-485 or RS-232 and transmits it through the mobile network to a metering or dispatch server.
- the meter measures resource consumption;
- the modem reads data through the serial interface;
- information is sent through GSM/GPRS;
- the server receives and stores the data;
- the operator views it in the metering application.
🔌 RS-485 and RS-232 interfaces
RS-485 is commonly used for industrial meters and controllers and is suitable for communication in electrically noisy installations.
RS-232 is intended for devices with a serial COM port, flow computers and configuration equipment.
Before connection, verify the communication protocol, baud rate, parity, stop bits and cable pinout.
📶 GSM/GPRS transmission
The modem operates on 2G mobile networks in the GSM 900/1800 bands. An active SIM card and available 2G coverage are required.
Depending on the exact hardware and firmware version, supported modes may include:
- GPRS;
- TCP/IP;
- CSD;
- SMS commands;
- transparent serial-data transmission.
🏭 Compatible equipment types
- gas meters and volume correctors;
- electricity meters;
- heat meters;
- water flow meters;
- gas flow computers;
- industrial controllers;
- sensors and data loggers;
- telemetry equipment;
- automated gas- and electricity-metering systems.
Important: a standard pulse-output meter cannot normally be connected directly unless a compatible pulse-to-RS-485 or pulse-to-RS-232 converter is installed.
📊 Remote-metering capabilities
- automatic collection of readings;
- fewer manual site visits;
- monitoring of remote facilities;
- consumption archiving;
- transmission of process parameters;
- diagnostic-message collection;
- dispatch-system integration;
- centralised monitoring of multiple sites.
🔋 Power supply
The Schetchik.uz product listing specifies a supplied mains power adapter. Verify its output voltage, current rating and connector polarity before use.
📡 SIM card and mobile service
- disable the SIM PIN request;
- verify 2G coverage at the site;
- enter the mobile operator’s APN;
- check the tariff and account balance;
- configure the server address and port;
- position the antenna where signal quality is stable.
The SIM card and cellular service are normally purchased separately.
✅ Key advantages
- RS-485 and RS-232 interfaces;
- GSM/GPRS data transmission;
- 2G GSM 900/1800 support;
- connectivity for different metering devices;
- automated-metering integration;
- remote reading collection;
- suitable for sites without wired internet;
- mains power adapter included;
- centralised monitoring capability.
🏢 Applications
- industrial facilities;
- boiler houses;
- gas-distribution stations;
- transformer substations;
- municipal facilities;
- gas, water, heat and electricity metering stations;
- warehouses and remote production sites;
- telemetry and dispatch systems;
- automated commercial-metering systems.
📦 Package contents
- BitCord RS-485/RS-232 GSM/GPRS modem;
- mains power adapter;
- packaging.
Confirm whether the antenna, RS-232 cable, RS-485 terminal, product passport and warranty card are included in the supplied batch.
⚠️ Confirm before ordering
- exact BitCord hardware model;
- compatibility with the connected meter;
- supported meter protocol;
- GPRS TCP/IP or CSD operating mode;
- SMS-command support;
- supported mobile frequency bands;
- number and format of SIM cards;
- antenna and interface-cable inclusion;
- power-adapter output voltage;
- operating-temperature range;
- enclosure protection rating;
- mounting method;
- compatible server software;
- warranty and exact package contents.
⚠️ Important: the presence of an RS-485 or RS-232 port does not guarantee compatibility with every meter. Both devices must use compatible serial-port settings and communication protocols.

BitCord RS-485/RS-232 GSM/GPRS data-transmission modem
📡 The BitCord RS-485/RS-232 is an industrial modem designed to transmit data remotely from meters, controllers, flow computers and other equipment through a GSM/GPRS mobile network.
It supports 2G communication in the GSM 900/1800 bands and provides two industrial serial interfaces: RS-485 and RS-232.
🔄 Operating principle
A connected meter or controller generates consumption and equipment-status data. The modem reads this information through RS-485 or RS-232 and transmits it through the mobile network to a metering or dispatch server.
- the meter measures resource consumption;
- the modem reads data through the serial interface;
- information is sent through GSM/GPRS;
- the server receives and stores the data;
- the operator views it in the metering application.
🔌 RS-485 and RS-232 interfaces
RS-485 is commonly used for industrial meters and controllers and is suitable for communication in electrically noisy installations.
RS-232 is intended for devices with a serial COM port, flow computers and configuration equipment.
Before connection, verify the communication protocol, baud rate, parity, stop bits and cable pinout.
📶 GSM/GPRS transmission
The modem operates on 2G mobile networks in the GSM 900/1800 bands. An active SIM card and available 2G coverage are required.
Depending on the exact hardware and firmware version, supported modes may include:
- GPRS;
- TCP/IP;
- CSD;
- SMS commands;
- transparent serial-data transmission.
🏭 Compatible equipment types
- gas meters and volume correctors;
- electricity meters;
- heat meters;
- water flow meters;
- gas flow computers;
- industrial controllers;
- sensors and data loggers;
- telemetry equipment;
- automated gas- and electricity-metering systems.
Important: a standard pulse-output meter cannot normally be connected directly unless a compatible pulse-to-RS-485 or pulse-to-RS-232 converter is installed.
📊 Remote-metering capabilities
- automatic collection of readings;
- fewer manual site visits;
- monitoring of remote facilities;
- consumption archiving;
- transmission of process parameters;
- diagnostic-message collection;
- dispatch-system integration;
- centralised monitoring of multiple sites.
🔋 Power supply
The Schetchik.uz product listing specifies a supplied mains power adapter. Verify its output voltage, current rating and connector polarity before use.
📡 SIM card and mobile service
- disable the SIM PIN request;
- verify 2G coverage at the site;
- enter the mobile operator’s APN;
- check the tariff and account balance;
- configure the server address and port;
- position the antenna where signal quality is stable.
The SIM card and cellular service are normally purchased separately.
✅ Key advantages
- RS-485 and RS-232 interfaces;
- GSM/GPRS data transmission;
- 2G GSM 900/1800 support;
- connectivity for different metering devices;
- automated-metering integration;
- remote reading collection;
- suitable for sites without wired internet;
- mains power adapter included;
- centralised monitoring capability.
🏢 Applications
- industrial facilities;
- boiler houses;
- gas-distribution stations;
- transformer substations;
- municipal facilities;
- gas, water, heat and electricity metering stations;
- warehouses and remote production sites;
- telemetry and dispatch systems;
- automated commercial-metering systems.
📦 Package contents
- BitCord RS-485/RS-232 GSM/GPRS modem;
- mains power adapter;
- packaging.
Confirm whether the antenna, RS-232 cable, RS-485 terminal, product passport and warranty card are included in the supplied batch.
⚠️ Confirm before ordering
- exact BitCord hardware model;
- compatibility with the connected meter;
- supported meter protocol;
- GPRS TCP/IP or CSD operating mode;
- SMS-command support;
- supported mobile frequency bands;
- number and format of SIM cards;
- antenna and interface-cable inclusion;
- power-adapter output voltage;
- operating-temperature range;
- enclosure protection rating;
- mounting method;
- compatible server software;
- warranty and exact package contents.
⚠️ Important: the presence of an RS-485 or RS-232 port does not guarantee compatibility with every meter. Both devices must use compatible serial-port settings and communication protocols.