GPRS-module for EX18 and EX518
GPRS data-transmission module for EX18 and EX518 electricity meters
📡 The GPRS module for EX18 and EX518 is a communication device designed to transmit electronic electricity-meter readings automatically to a remote server or automated metering platform.
It is compatible with:
- EX18 — a single-phase electronic electricity meter;
- EX518 — a three-phase electronic electricity meter.
📲 Operating principle
The electricity meter measures energy consumption and stores its data internally. The GPRS module reads the information through the RS-485 interface and sends it through a GSM/GPRS mobile network to the metering server.
- the EX18 or EX518 measures electricity consumption;
- the module reads the data through RS-485;
- the information is transmitted through the mobile network;
- the server receives and stores the data;
- the user views readings in an AMR or dispatch application.
📶 GSM/GPRS transmission
The module uses a mobile network to transmit small data packets. This is convenient at sites without wired internet access.
Operation generally requires:
- an active SIM card;
- GSM/GPRS coverage;
- correct APN settings;
- server address and port;
- registration of the meter in the metering platform.
Confirm whether a SIM card is included. Cellular service is normally paid for separately.
🔌 RS-485 interface
The module communicates with the electricity meter through the industrial RS-485 serial interface.
Installation must observe:
- correct A and B polarity;
- the manufacturer’s wiring diagram;
- permissible cable length;
- screening and grounding requirements;
- communication speed;
- the meter’s network address.
🔐 DLMS protocol
EX18 and EX518 meters use specialised communication protocols. The manufacturer specifies DLMS TCP/IP for GPRS communication and a DLMS-family protocol for the RS-485 port.
📊 Data that may be transmitted
- accumulated active energy;
- reactive energy;
- tariff-zone readings;
- voltage;
- current;
- power;
- power factor;
- date and time;
- load profile;
- power-failure and restoration events;
- diagnostic information.
The exact available data depends on the meter version and metering software.
🏢 Automated electricity metering
The module can operate as part of an automated meter-reading or electricity-metering system.
- reduces manual meter-reading visits;
- reduces data-entry errors;
- accelerates reporting;
- enables remote consumption monitoring;
- compares consumption across periods;
- allows several sites to be monitored centrally;
- provides access to archived data.
🌡️ Operating conditions
The stated operating-temperature range is −10 to +45 °C. The module should normally be installed inside a protected electrical enclosure.
📡 Mobile-signal quality
A metal electrical cabinet may reduce mobile-network signal strength. Communication should be tested before final installation.
Where signal strength is low, it may be necessary to:
- change the module location;
- install an external antenna;
- place the antenna outside the metal cabinet;
- use a SIM card from another operator;
- verify APN settings.
✅ Key advantages
- compatible with EX18 and EX518;
- automatic transmission of meter readings;
- RS-485 interface;
- GSM/GPRS communication;
- DLMS protocol support;
- supports single- and three-phase meters;
- reduces manual meter-reading requirements;
- integration with automated metering systems;
- suitable for remote sites;
- communication cable included;
- one-year official warranty;
- Uzstandard certificate.
🏭 Applications
- private houses;
- apartments and residential complexes;
- shops and offices;
- industrial facilities;
- warehouses;
- business centres;
- municipal facilities;
- transformer substations;
- electrical distribution panels;
- automated electricity-metering sites.
📦 Package contents
- GPRS module for EX18 and EX518;
The SIM card, mobile tariff, server and software may not be included in the standard package.
🔧 Installation recommendations
- disconnect the electrical supply before installation;
- verify compatibility with the exact meter modification;
- connect RS-485 according to the wiring diagram;
- do not reverse the A and B terminals;
- configure the meter address and communication speed;
- install an active SIM card;
- enter the mobile operator’s APN settings;
- configure the server address and port;
- check GSM signal strength;
- perform a test transmission;
- compare remote data with the meter display;
- install the module inside a protected electrical enclosure.
⚠️ Confirm before ordering
- exact EX18 or EX518 modification;
- firmware compatibility;
- connector type and wiring diagram;
- module supply voltage;
- power-supply unit inclusion;
- supported GSM frequency bands;
- supported mobile operator;
- antenna type and inclusion;
- SIM-card format;
- whether the SIM card is included;
- compatible AMR server;
- software and licence requirements;
- DLMS communication settings;
- remote-configuration capability;
- enclosure protection rating;
- dimensions and mounting method;
- exact package contents.
⚠️ Important: the module will not begin transmitting data merely after the cable is connected. The SIM card, network parameters, electricity meter and server must be configured correctly.
⚡ Installation and configuration should be carried out by a qualified electrical specialist.







 СН4 мал 200.jpg)










.jpg)
.jpg)