UR-Series | Ultrasonic Liquid Flow Meter | South Korea
Leave a review
Description
1. Description
CMENTECH flowmeters use a multi-line measurement technique during passage, which is designed to accurately measure the flow rate (± 0.20 ~ 0.5% of the actual flow rate) in pipes. Depending on the accuracy requirements, the flowmeters can be configured to work with 1-10 acoustic routes.
2. The principle of measurement
This meter uses multipath ultrasonic waves to measure the average velocity of the fluid lines on the cross-sectional area of the fluid and calculates the flow volume without any coefficients, applying a double integral formula to the velocity and area distribution. (Patented) This method minimizes measurement errors due to a complex velocity profile with set conditions (near elbows, valves, pumps, etc.)
3. Features and application
a. High accuracy of measurement of Reynolds number and coefficient of friction has no effect. Errors do not occur due to the thickness of the pipe, the scale of the lining and the signal time.
b. High accuracy with short straight pipe and low flow rate.
c. With a large measurement range (maximum/minimum flow), a measurement based on the measured value (MV) rather than the full scale deviation (FS) negates the effect of the flow range.
d. Installation without stopping the flow (hot plug) and replacement of the built-in sensor. Ultrasonic transducers are directly installed in
an existing pipe without stopping the flow of liquid. This mounting method is great for large diameter pipes due to its low cost and convenience.
It can also achieve higher accuracy.
e. Calibration tests in one place (dry calibration method) have been obtained and certified by the Korean Center for Standard Scientific Research for this
функции. (KS B 5640), ANSI ASME MFC -5M (1985), ASME PTC-18 (2002), IEC 600041, ANSI /AWWA C750-03.
f. Data logging: 32,000 data (stream date, power on/off, coefficient, reset and error code).
g. Diagnostics: Empty, Power on/off, coefficient, reset and error code.
h. Automatic correction of zero flow and signal.
i. Automatic flow profile compensation for path loss.
j. Applications: circulation of tap water, wastewater, industrial water, seawater, oil, wastewater, beverages, process water and
cooling liquid, as well as cold water circulation for chemical and quiet manufacturing enterprises.
k. Warranty: one year of full labor and spare parts.
l. Price: very competitive
4. Characteristics
Technical specifications |
|
Branches of application |
Faucet, sewer, waste, industrial, seawater, hydrocarbon, crude oil, LNG, beverages, clean water, etc. |
The principle of measurement |
Ultrasonic sensors for liquid (1~5 summer residents) |
Flow range |
-30 m/s ~ + 30 m/s (± 0.2 m/s, cut-off) |
diameter of the hardness |
Diameter from 20 mm to 10000 mm |
pulse frequency |
100 kHz ~ 2.5MHz |
Working environment temperature |
-30 ° C ~ + 60 ° C (опция: -40 ° C ~ + 180 ° C) PN 15, (опция PN20, 25, 40) |
Straight Section |
5D/2D |
material |
"Flow tube: carbon steel with epoxy coating (option: STS304, etc.). Sensor: PE, (option: Teflon, brass, 316 steel, Titanium)" |
Degree of protection |
IP68 |
Flanged connection |
Flange KSD3578, (option: Other Standard) |
Hot tapping |
Carbon steel, STS (option: ductile iron, PVC ( |
Signal cable |
US CABLE (RG 174-12 Core): 10 m (option: cable length with max. 150 m) |
Transmitter (controller) |
|
Type |
Separate from the flow tube |
CPU |
32-bit microprocessor |
display |
Graphic LCD Display 249 x 128 (Flow, Total Flow, SOS, Speed, Epty, Diagnostics, Signal) english, Korean |
accuracy |
± 0,20 ~ ± 0,5% (MV) |
permission |
<0,1 нс (<0,0005 м / с) |
linearity |
<0,05% (повторяемость <0,02%) |
* Input data |
DC 4 ~ 20 мА 2 порта, (варианты: порт D /O 2) |
Output data |
4~20 mA, 2 ports, frequency (1 kHz), (option: TMS, BCD, Relay, RS-485 (Modbus), 2 ports, HART, Profibus DB) |
Working condition |
-30 ° C ~ + 60 ° C (опция: -40 ° C ~ + 80 ° C) |
Data Logger |
32,000 data (date/stream /total/stream) (option: 300,000 PDA data) |
diagnostics |
Power on/off, Coefficient, Reset, Error code |
Unit of measurement |
m3, gallon, l, 9 digits (999999999), /h, min, s |
Power |
AC110~220V (50~60Hz), DC24V |
Power consumption |
15W |
Waterproof |
IP65, (option: IP67) |
measurement |
254 (W) × 330 (H) × 100 (D), 3 kg |
With a crankshaft |
|||
Number of sensors |
L1 |
L2 |
|
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,5% |
|
10D |
2D |
±0,25% |
|
With a T-shaped pipe |
|||
Number of sensors |
L1 |
L2 |
Error rate |
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,5% |
|
10D |
2D |
±0,25% |
|
When expanding the pipe |
|||
Number of sensors |
L1 |
L2 |
Error rate |
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,7% |
|
10D |
2D |
±0,5% |
|
With a reduction tube |
|||
Number of sensors |
L1 |
L2 |
Error rate |
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,5% |
|
10D |
2D |
±0,25% |
|
At the valve |
|||
Number of sensors |
L1 |
L2 |
Error rate |
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,7% |
|
10D |
2D |
±0,5% |
|
With a pumping system |
|||
Number of sensors |
L1 |
L2 |
Error rate |
5 |
3D |
2D |
±1,0% |
5D |
2D |
±0,7% |
|
10D |
2D |
±0,5% |
Characteristics
Installation object | Production, Company |
Type of water accounting | Cold water |
Connecting ASKUG | Yes |
Brand | HSCMT |
Accounting method | Ultrasonic |
Compound | Flanged |
Equipment | Device, Box, Mounting parts, Gaskets, Flanges, Passport, Manual, Warranty card, Software, Battery |
Country | South Korea |
Condition | New |
Доп. информация | |
IKPU | 0 |