Ener Ray Series | ultrasonic thermal energy flow meter | South Korea
Leave a review
Description
EnerRay is an ultrasonic heat meter specially designed for heating, cooling or combined heating/cooling in local and central heating systems.
EnerRay consists of an ultrasonic flow sensor;
calculator with built-in hardware and software for measuring flow, temperature and energy consumption;
Temperature sensor.
The principle of measurement
EnerRay flow unit and temperature sensor. The flow measurement method uses an advanced method |
differences in the propagation times of the ultrasonic wave. The ultrasonic wave propagation time difference method uses |
the principle according to which the transmission rate and direction of the ultrasonic pulse change depending on the velocity of the liquid. In each position, the flow rate |
it is based on the principle that the time when the ultrasonic pulse is transmitted in the direction of the fluid flow is faster than the time when it is transmitted in the opposite direction |
Features
A short straight pipe is required at the rear end of the bend (5D/2D) |
☞ Using a circuit that is fully field-tested using advanced noise reduction technology |
☞ The design of the STS316L sensor housing completely covers the ultrasonic generator, providing full protection from external shocks. |
☞ There are no moving parts inside |
☞ There is no pressure loss, and the flow measurement range is wide. |
Technical specifications
Flow Volume Specification |
||
Difference |
Small caliber |
Medium caliber |
The principle of measurement |
Ultrasound propagation time difference method |
|
Circuit Configuration |
Multiple reflection |
Reflexive method (Method V) |
Number of circuits |
1-2 chains |
2-3 chains |
Liquid temperature |
From 0 to 130 ° C |
|
Fluid conditions |
Turbidity: 5000 mg/l or less, Viscosity: 600 sP or less |
|
Water resistance |
IP68 |
|
Measuring range |
-15 ~ 16 m /s |
|
Caliber |
20, 25, 40 mm |
From 50 to 250 mm |
Flange opening |
Of 16 |
|
Specifications |
EN1434, OIML R75 |
|
Standard working part |
||
Difference |
Integral type |
Removable type |
Show Element |
Energy, total energy consumption, consumption, total consumption, SOS |
|
Grade assessment |
Расход: ± (2 + 0,02 кп /кв)%, калорийность: ± (3 + 4ΔΘмин /ΔΘ 0,02 кп /кв) |
|
Display unit |
Gcal, GJ, MWh |
|
exit |
RS-232 (485) |
|
IP class |
IP65 (IP67 option) |
|
Measurement period |
0.05s |
|
power |
AC 110/220 V |
|
Operating temperature |
-20 ~ 70 ℃ |
|
Temperature sensor (1 pair) |
||
Measuring man |
Thermistor (including thermistor well) |
|
model |
PT-100 |
ST-500 |
Measuring range |
From 0 to 130 ° C |
|
accuracy |
± 0,4 (0,05 ° C) |
Flow range
DN (PN16) |
20A |
25A |
40A |
50A |
65A |
80A |
100A |
125A |
150A |
200A |
250A |
Interfacial distance |
190 |
260 |
300 |
200 |
200 |
225 |
250 |
250 |
300 |
350 |
450 |
Overload flow |
3 |
14 |
20 |
30 |
50 |
90 |
140 |
200 |
300 |
500 |
1000 |
Maximum flow |
1,5 |
7 |
10 |
15 |
25 |
45 |
70 |
100 |
150 |
250 |
500 |
Minimum flow |
0,06 |
0,14 |
0,4 |
0,6 |
1 |
1,8 |
2,8 |
4 |
6 |
10 |
20 |
Time Flow |
0,03 |
0,03 |
0,1 |
0,15 |
0,2 |
0,25 |
0,5 |
0,8 |
1 |
1,5 |
2,5 |
Voltage Specification |
M12 |
M12 |
M16 |
M16 |
M16 |
M16 |
M16 |
M16 |
M20 |
M20 |
M24 |
Number of bolts |
4×2 |
4×2 |
4×2 |
4×2 |
4×2 |
8×2 |
8×2 |
8×2 |
8×2 |
12×2 |
12×2 |
Characteristics
Installation object | Production, Company |
Type of water accounting | Hot water |
Connecting ASKUG | Yes |
Brand | HSCMT |
Accounting method | Ultrasonic |
Compound | Flanged |
Equipment | Device, Box, Mounting parts, Gaskets, Flanges, Temperature sensor, Passport, Manual, Warranty card, Software, Battery |
Country | South Korea |
Condition | New |
Доп. информация | |
IKPU | 0 |